27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Film thickness
Int. Ø
Length
Specifications
Compare models£409.31
Inc. VAT
The Trajan Scientific Capillary Column GC BP5MS, 0.25mm ID x 0.25 µm x 15 m length is engineered for high-performance gas chromatography applications. Featuring a non-polar 5% phenyl polysilphenylene-siloxane stationary phase, this column offers very low bleed and high thermal stability, making it ideal for analyzing a wide range of compounds including pesticides, herbicides, hydrocarbons, amines, and phenols. Its robust construction ensures reliable performance in GC-MS systems.
This capillary column is an essential tool for laboratories requiring precise and reliable chromatographic separations.
£409.31
Inc. VAT
Manufacturer P/N
054308
Part Number
4.682 386
Manufacturer
Trajan Scientific
Film thickness
0.25 µm
£1,033.08
Inc. VAT
Manufacturer P/N
054321
Part Number
4.682 388
Manufacturer
Trajan Scientific
Film thickness
0.25 µm
£693.05
Inc. VAT
Manufacturer P/N
054301
Part Number
4.682 385
Manufacturer
Trajan Scientific
Film thickness
0.18 µm
£759.16
Inc. VAT
Manufacturer P/N
054320
Part Number
4.682 387
Manufacturer
Trajan Scientific
Film thickness
0.25 µm
£795.48
Inc. VAT
Manufacturer P/N
054310
Part Number
4.676 266
Manufacturer
Trajan Scientific
Film thickness
0.25 µm
It is engineered for high-performance gas chromatography applications. Featuring a non-polar 5% phenyl polysilphenylene-siloxane stationary phase, this column offers very low bleed and high thermal stability, making it ideal for analyzing a wide range of compounds including pesticides, herbicides, hydrocarbons, amines, and phenols. Its robust construction ensures reliable performance in GC-MS systems.
Yes. It is designed for GC-MS analysis of pesticides, herbicides, hydrocarbons, amines, and phenols, and offers a stationary phase of 5% phenyl polysilphenylene-siloxane and an inner diameter of 0.25 mm to support this kind of work.
It has a stationary phase of 5% phenyl polysilphenylene-siloxane, an inner diameter of 0.25 mm and a film thickness of 0.25 µm.
It offers -40°C to +330/350°C.

27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure

19 mins read
SPE Consumables Procurement Checklist for UK Analytical Laboratories

24 mins read
Bottle Labelling and Traceability for Lab Managers - Reducing Confusion, Waste and Reorder Errors

21 mins read
How to Standardise Pipette Tip Procurement Across Laboratory Teams

33 mins read
Dissolved Oxygen Calibration and Verification for Laboratory Measurement