Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Colour septa
Material septa
Shore hardness
Slit
Thickness
With hole
Specifications
Compare models£39.07
Inc. VAT
The Macherey-Nagel N 13 PP Screw Cap is a black polypropylene screw cap for N 13 chromatography vials fitted with a Silicone White/PTFE Blue septum. The cap has a centre hole. Septum hardness is 45° Shore A and thickness 1.5 mm. Manufacturer part number 702925.
Combine with matching N 13 vials from Macherey-Nagel and check septum material against your solvents and injection method.
£39.07
Inc. VAT
Manufacturer P/N
702925
Part Number
4.730 643
Manufacturer
Macherey-Nagel
Colour septa
White/blue
£35.90
Inc. VAT
Manufacturer P/N
702052
Part Number
6.316 979
Manufacturer
Macherey-Nagel
Colour septa
White/red
£28.62
Inc. VAT
Manufacturer P/N
702051
Part Number
4.678 720
Manufacturer
Macherey-Nagel
Colour septa
Red/transparent
£27.24
Inc. VAT
Manufacturer P/N
702050
Part Number
4.690 381
Manufacturer
Macherey-Nagel
Colour septa
Red/transparent
£34.64
Inc. VAT
Manufacturer P/N
702926
Part Number
4.001 566
Manufacturer
Macherey-Nagel
Colour septa
White/red
Manufacturer P/N
702963
Part Number
4.730 642
Manufacturer
Macherey-Nagel
Colour septa
-
Manufacturer P/N
702966
Part Number
4.730 641
Manufacturer
Macherey-Nagel
Colour septa
-
It is used to close N 13 chromatography vials for sample storage and autosampler injection.
It uses a Silicone White/PTFE Blue septum, cross-slit.
Hardness 45° Shore A, thickness 1.5 mm.
It fits vials with N 13 screw necks. Check the closure size of your vials before ordering.
The Agilent 5182-0717 Screw Cap is a blue polypropylene screw cap with PTFE/red silicone septum for 9-425 thread vials, supplied 100 per pack. By comparison, the Macherey-Nagel N 13 PP Screw Cap is a black polypropylene screw cap for N 13 chromatography vials fitted with a Silicone White/PTFE Blue septum. Choose the Macherey-Nagel product when your method or existing set-up specifies it; the Agilent product may be preferable if your laboratory is standardised on Agilent consumables and tools. They are made for different closure sizes, so they are alternatives rather than interchangeable parts.

27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure

19 mins read
SPE Consumables Procurement Checklist for UK Analytical Laboratories

24 mins read
Bottle Labelling and Traceability for Lab Managers - Reducing Confusion, Waste and Reorder Errors

21 mins read
How to Standardise Pipette Tip Procurement Across Laboratory Teams

33 mins read
Dissolved Oxygen Calibration and Verification for Laboratory Measurement