Optimise Your Pipetting Accuracy with Compatible Pipette Tips
17 mins read
Pipette Tip Selection Guide

By Donal O’Sullivan, BSc. Reviewed by Michael Anderson, MBA.
Pipette Tip Compatibility Guide: Accuracy & Selection | LabFriend UK
The precision of even the most advanced pipette is only as reliable as the tip you attach to it. Using low-quality or incompatible tips is a primary cause of measurement error and can compromise the airtight seal required for reproducible results. To safeguard your research and ensure a perfect fit, selecting the right tip is essential.
Choosing the Right Tip for Your Application
Different laboratory workflows require specific tip characteristics to ensure sample integrity. Below is a guide to selecting the most suitable tip for your needs:
| Application | Recommended Tip Type |
| PCR / Molecular Biology | Filter tips |
| Contamination-Sensitive Assays | Filter tips |
| Sterile Routine Pipetting | Racked tips |
| High-Volume / Cost-Sensitive Work | Economy (Bulk) tips |
Understanding Tip Characteristics
- Filter Tips: Feature an aerosol barrier to prevent cross-contamination between the pipette and the sample.
- Racked Tips: Pre-sterilized and supplied in racks (typically 96 tips) to minimize contamination risk and increase convenience.
- Economy Tips: Non-sterile polypropylene tips supplied in bulk bags, offering a cost-effective solution for high-throughput labs

Maximum Accuracy: The Low-Retention Advantage
To achieve true pipetting accuracy, every microliter must be expelled from the tip. LLG Labware low-retention racked tips are engineered specifically for this purpose.
- Purity: These tips are certified DNase, RNase, and pyrogen-free.
- Sustainability: Economical refills maximize lab space and reduce environmental impact while protecting your budget.
- Variety: Available in sterile racked versions or convenient rack refill systems.
LLG Labware Universal Compatibility for Major Brands
A common concern is whether the same tip will work across different pipette brands. Our range is designed to deliver a secure, leak-proof seal for all major manufacturers, including Sartorius, BRAND, Thermo Scientific, and Biohit
| Pipette Brand | Popular Models Supported | Volume Range Coverage | Channel Support |
| Biohit | mLine, Proline | 0.1µL to 1000µL | 1, 8, 12 |
| Brand | Transferpette, Transferpette S | 0.1µL to 1000µL | 1, 8, 12 |
| Eppendorf | Research Plus, Reference | 0.1µL to 1000µL | 1, 8, 12 |
| Gilson | Pipetman Classic, G, L, P10L | 0.2µL to 1000µL | 1, 8, 12 |
| Nichiryo | Nichipet | 0.1µL to 1000µL | 1, 8, 12 |
| Rainin | Pipet-Lite, Classic | 0.1µL to 1000µL | 1, 8, 12 |
| Thermo/Finn | Finnpette 4500 | 0.2µL to 1000µL | 1, 8, 12 |
| Socorex | Calibra, Acura | 0.1µL to 1000µL | 1, 8, 12 |
LLG Labware Specific Compatibility Table
4.694 458 (10x96), 4.694 459 (10x96) and 4.694 460 (8x96) are Sterile, Racked Tips DNase, RNase and pyrogen Free
4.694 454 (10x96), 4.694 455 (10x96) and 4.654 456 (8x96) are Sterile, Rack Refill Tips DNase, RNase and pyrogen Free - Refill Option
| Brand | Model | Volume Range | Channels |
Compatible Part No. 4.694 458 / 4.694 454* 0.1–10µl |
Compatible Part No. 4.694 459 / 4.694 455* 200µl |
Compatible Part No. 4.694 460 / 4.694 456* 1250µl |
| Biohit | mLine | 0.1–3µl | 1 | X | ||
| Biohit | mLine | 0.5–10µl | 1 | X | ||
| Biohit | mLine | 2–20µl | 1 | X | ||
| Biohit | mLine | 10–100µl | 1 | X | ||
| Biohit | mLine | 20–200µl | 1 | X | ||
| Biohit | mLine | 100–1000µl | 1 | X | ||
| Biohit | mLine | 0.5–10µl | 8/12 | X | ||
| Biohit | mLine | 5–100µl | 8/12 | X | ||
| Biohit | mLine | 30–300µl | 8/12 | |||
| Biohit | Proline | 0.1–2.5µl | 1 | X | ||
| Biohit | Proline | 0.5–10µl | 1 | X | ||
| Biohit | Proline | 2–20µl | 1 | X | ||
| Biohit | Proline | 5–50µl | 1 | X | ||
| Biohit | Proline | 10–100µl | 1 | X | ||
| Biohit | Proline | 20–200µl | 1 | X | ||
| Biohit | Proline | 100–1000µl | 1 | X | ||
| Biohit | Proline | 0.5–10µl | 8/12 | X | ||
| Biohit | Proline | 5–50µl | 8/12 | X | ||
| Biohit | Proline | 50–300µl | 8/12 | |||
| Brand | Transferpette | 0.1–1µl | 1 | X | ||
| Brand | Transferpette | 0.5–10µl | 1 | X | ||
| Brand | Transferpette | 2–20µl micro | 1 | X | ||
| Brand | Transferpette | 2–20µl | 1 | X | ||
| Brand | Transferpette | 5–50µl | 1 | X | ||
| Brand | Transferpette | 10–100µl | 1 | X | ||
| Brand | Transferpette | 20–200µl | 1 | X | ||
| Brand | Transferpette | 100–1000µl | 1 | X | ||
| Brand | Transferpette | 0.5–10µl | 8/12 | X | ||
| Brand | Transferpette | 2–20µl | 8/12 | X | ||
| Brand | Transferpette | 2.5–25µl | 8/12 | X | ||
| Brand | Transferpette | 5–50µl | 8/12 | X | ||
| Brand | Transferpette | 10–100µl | 8/12 | X | ||
| Brand | Transferpette | 20–200µl | 8/12 | X | ||
| Brand | Transferpette | 30–300µl | 8/12 | |||
| Brand | Transferpette | 0.1–1µl | 1 | X | ||
| Brand | Transferpette | 0.1–2.5µl | 1 | X | ||
| Brand | Transferpette | 0.5–10µl | 1 | X | ||
| Brand | Transferpette | 2–20µl | 1 | X | ||
| Brand | Transferpette | 10–100µl | 1 | X | ||
| Brand | Transferpette | 20–200µl | 1 | X | ||
| Brand | Transferpette | 100–1000µl | 1 | X | ||
| Brand | Transferpette | 0.5–10µl | 8/12 | X | ||
| Brand | Transferpette | 5–50µl | 8/12 | X | ||
| Brand | Transferpette | 10–100µl | 8/12 | X | ||
| Brand | Transferpette | 20–200µl | 8/12 | X | ||
| Brand | Transferpette | 30–300µl | 8/12 | |||
| Eppendorf | Research Plus | 0.1–2.5µl | 1 | X | ||
| Eppendorf | Research Plus | 0.5–10µl | 1 | X | ||
| Eppendorf | Research Plus | 2–20µl micro | 1 | X | ||
| Eppendorf | Research Plus | 2–20µl | 1 | X | ||
| Eppendorf | Research Plus | 10–100µl | 1 | X | ||
| Eppendorf | Research Plus | 20–200µl | 1 | X | ||
| Eppendorf | Research Plus | 30–300µl | 1 | |||
| Eppendorf | Research Plus | 100–1000µl | 1 | X | ||
| Eppendorf | Research Plus | 0.5–10µl | 8/12 | X | ||
| Eppendorf | Research Plus | 10–100µl | 8/12 | X | ||
| Eppendorf | Research Plus | 30–300µl | 8/12 | |||
| Eppendorf | Reference | 0.1–2.5µl | 1 | X | ||
| Eppendorf | Reference | 0.5–10µl | 1 | X | ||
| Eppendorf | Reference | 2–20µl micro | 1 | X | ||
| Eppendorf | Reference | 2–20µl | 1 | X | ||
| Eppendorf | Reference | 10–100µl | 1 | X | ||
| Eppendorf | Reference | 50–200µl | 1 | X | ||
| Eppendorf | Reference | 100–1000µl | 1 | X | ||
| Gilson | Pipetman Classic, G, L: P2 | 0.2–2µl | 1 | X | ||
| Gilson | Pipetman Classic, G, L: P2 | 1–10µl | 1 | X | ||
| Gilson | Pipetman Classic, G, L: | 2–20µl | 1 | X | ||
| Gilson | Pipetman Classic, G, L: | 20–100µl | 1 | X | ||
| Gilson | Pipetman Classic, G, L: | 50–200µl | 1 | X | ||
| Gilson | Pipetman Classic, G, L: | 200–1000µl | 1 | X | ||
| Gilson | Pipetman P10L | 0.5–10µl | 8/12 | X | ||
| Gilson | Pipetman P10L | 2–20µl | 8/12 | X | ||
| Gilson | Pipetman P10L | 20–200µl | 8/12 | X | ||
| Gilson | Pipetman P300L | 20–300µl | 8/12 | |||
| LLG Labware | proMLP | 0.2–2µl | 1 | X | ||
| LLG Labware | proMLP | 0.5–10µl | 1 | X | ||
| LLG Labware | proMLP | 2–20µl | 1 | X | ||
| LLG Labware | proMLP | 10–100µl | 1 | X | ||
| LLG Labware | proMLP | 20–200µl | 1 | X | ||
| LLG Labware | proMLP | 100–1000µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 5µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 10µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 20µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 25µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 50µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 100µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 200µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 250µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 500µl | 1 | X | ||
| LLG Labware | Microliter pipette, fix | 1000µl | 1 | X | ||
| LLG Labware | Microliter pipette, variable | 0.1–2.5µl | 1 | X | ||
| LLG Labware | Microliter pipette, variable | 0.5–10µl | 1 | X | ||
| LLG Labware | Microliter pipette, variable | 2–20µl | 1 | X | ||
| LLG Labware | Microliter pipette, variable | 10–100µl | 1 | X | ||
| LLG Labware | Microliter pipette, variable | 20–200µl | 1 | X | ||
| LLG Labware | Microliter pipette, variable | 100–1000µl | 1 | X | ||
| Nichiryo | Nichipet Premium, EX, EX | 0.1–2µl | 1 | X | ||
| Nichiryo | Nichipet Premium, EX, EX | 2–20µl | 1 | X | ||
| Nichiryo | Nichipet Premium, EX, EX | 10–100µl | 1 | X | ||
| Nichiryo | Nichipet Premium, EX, EX | 20–200µl | 1 | X | ||
| Nichiryo | Nichipet Premium, EX, EX | 100–1000µl | 1 | X | ||
| Nichiryo | Nichipet 7000 | 0.5–10µl | 8/12 | X | ||
| Nichiryo | Nichipet 7000 | 5–50µl | 8/12 | X | ||
| Nichiryo | Nichipet 7000 | 40–200µl | 8/12 | X | ||
| Nichiryo | Nichipet 7000 | 50–300µl | 8/12 | |||
| Rainin | Pipet-Lite SL-2XLS | 0.1–2µl | 1 | X | ||
| Rainin | Pipet-Lite SL-2XLS | 0.5–10µl | 1 | X | ||
| Rainin | Pipet-Lite SL-20XLS | 2–20µl | 1 | X | ||
| Rainin | Pipet-Lite SL-20XLS | 10–100µl | 1 | X | ||
| Rainin | Pipet-Lite SL-20XLS | 20–200µl | 1 | X | ||
| Rainin | Pipet-Lite | 20–300µl | 1 | |||
| Rainin | Pipet-Lite | 100–1000µl | 1 | X | ||
| Rainin | Classic PR-2 | 0.1–2µl | 1 | X | ||
| Rainin | Classic PR-2 | 0.5–10µl | 1 | X | ||
| Rainin | Classic PR-20 | 2–20µl | 1 | X | ||
| Rainin | Classic PR-20 | 10–100µl | 1 | X | ||
| Rainin | Classic PR-20 | 20–200µl | 1 | X | ||
| Rainin | Classic PR-1000 | 100–1000µl | 1 | X | ||
| Socorex | Calibra 822 | 0.2–2µl | 1 | X | ||
| Socorex | Calibra 822 | 1–10µl | 1 | X | ||
| Socorex | Calibra 822 | 2–20µl | 1 | X | ||
| Socorex | Calibra 822 | 10–100µl | 1 | X | ||
| Socorex | Calibra 822 | 20–200µl | 1 | X | ||
| Socorex | Calibra 822 | 100–1000µl | 1 | X | ||
| Socorex | Calibra 852 | 1–10µl | 8 | X | ||
| Socorex | Calibra 852 | 10–100µl | 8/12 | X | ||
| Socorex | Calibra 852 | 20–200µl | 8/12 | X | ||
| Socorex | Acura 825 | 0.1–2µl | 1 | X | ||
| Socorex | Acura 825 | 0.5–10µl | 1 | X | ||
| Socorex | Acura 825 | 1–10µl | 1 | X | ||
| Socorex | Acura 825 | 2–20µl | 1 | X | ||
| Socorex | Acura 825 | 5–50µl | 1 | X | ||
| Socorex | Acura 825 | 10–100µl | 1 | X | ||
| Socorex | Acura 825 | 20–200µl | 1 | X | ||
| Socorex | Acura 825 | 100–1000µl | 1 | X | ||
| Socorex | Acura 825 | 0.5–10µl | 8/12 | X | ||
| Socorex | Acura 825 | 5–50µl | 8/12 | X | ||
| Socorex | Acura 825 | 2–20µl | 8/12 | X | ||
| Socorex | Acura 825 | 40–350µl | 8/12 | |||
| Thermo/Finn | Finnpette 4500 | 0.2–2µl | 1 | X | ||
| Thermo/Finn | Finnpette 4500 | micro | 1 | X | ||
| Thermo/Finn | Finnpette 4500 | 0.5–5µl | 1 | X | ||
| Thermo/Finn | Finnpette 4500 | 2–20µl | 1 | X | ||
| Thermo/Finn | Finnpette 4500 | 5–50µl | 1 | X | ||
| Thermo/Finn | Finnpette 4500 | 100–1000µl | 1 | X | ||
| Thermo/Finn | Finnpette 4500 | 0.5–10µl | 8/12 | X | ||
| Thermo/Finn | Finnpette 4500 | 5–50µl | 8/12 | X | ||
| Thermo/Finn | Finnpette 4500 | 50–300µl | 8/12 |
* Refill Option
Switching to a refill system is an effective way to enhance laboratory sustainability without compromising on quality or performance. By opting for our pipette tip refill packs instead of standard boxed sets, you significantly reduce plastic waste and environmental impact, as the system allows you to reuse existing racks. Beyond the ecological benefits, these economical refills help you maximize valuable lab storage space and protect your budget, while still maintaining the rigorous DNase, RNase, and pyrogen-free standards required for sensitive research
Technical & Compatibility FAQ
Which pipette brands are compatible with LLG Labware tips?
LLG Labware low-retention tips are designed for universal fitment with major industry brands. This includes, but is not limited to:
-
Eppendorf: Research Plus and Reference models.
-
Gilson: Pipetman Classic, G, and L series.
-
Brand: Transferpette and Transferpette S.
-
Thermo Scientific: Finnpipette 4500 and various micro models.
-
Sartorius/Biohit: mLine and Proline pipettes.
What is the difference between Racked, Filter, and Economy tips?
Choosing the right format depends on your sterility requirements and budget:
-
Filter Tips: Best for molecular biology and PCR to prevent aerosol contamination.
-
Racked Tips: Ideal for sterile routine pipetting and diagnostics, provided in a convenient 96-tip tray.
-
Economy (Bulk) Tips: The most cost-effective solution for high-volume, non-sterile routine liquid handling.
Are LLG Labware tips certified free of contaminants?
Yes. The LLG Labware low-retention racked tips and rack refill systems are certified DNase, RNase, and pyrogen-free. This ensures they are suitable for sensitive molecular biology assays and contamination-sensitive research.
Why is "Low-Retention" important for pipetting accuracy?
For maximum accuracy, every microliter of liquid needs to be expelled from the tip. Low-retention technology reduces the amount of liquid that sticks to the inner walls of the tip, ensuring precise volume delivery and minimizing sample loss.
How do I match the correct tip volume to my pipette?
You must match the volume range of your pipette to the corresponding tip size to ensure an airtight seal. For example:
-
0.1–10µl pipettes typically require tips with reference code 4.694 458 or 4.694 454.
-
20–200µl pipettes generally utilize tips with reference code 4.694 459 or 4.694 455.
-
100–1000µl pipettes require the larger 4.694 460 or 4.694 456 variants.
Browse our complete range of pipette tips here
Want to know more see our other articles that may be of interest
The Complete Guide to Pipette Tips, Pipetting Accuracy & Laboratory Liquid Handling
How to Choose the Right Pipette: The Ultimate Guide to Accuracy and Lab Efficiency
Written by: Donal O’Sullivan, BSc, Co-Founder and Sales Director, LabFriend UK. Donal brings deep chemistry-led technical expertise across analytical chemistry, biochemistry, environmental monitoring, laboratory instrumentation, consumables and scientific product selection.
Reviewed by: Michael Anderson, MBA, Founder and Managing Director, LabFriend UK. Michael reviews LabFriend UK content for customer relevance, commercial accuracy, operational practicality and alignment with LabFriend UK’s laboratory supply model.
Frequently asked questions
Delivery times vary by product and supplier. Each product page shows current stock levels and the expected lead time, and we confirm this when you place your order. Most items arrive within 2 to 3 weeks. Specialised items can take longer if they are not in stock. If you need something by a certain date, contact us and we’ll check for you.
Yes. Register for a commercial account and, once it’s approved, you will be able to process orders via PO Once you have a commercial account, you can directly email your purchase orders
Add products to your cart and click Get a Quote. You’ll get a formal quote instantly, ready to send to your email address. For bulk orders or custom requirements, send us your product list and we’ll reply with itemized pricing.
If your item is faulty, not as described or sent in error, let us know within 14 days of delivery and we’ll arrange a return. Change of mind returns are only accepted if the item is unused and in its original packaging. A restocking fee will apply and you pay the return freight. Read our full Returns Policy for details.
Yes, prices are shown including GST by default. Use the Prices Inc. GST toggle at the top of the page to view prices without GST.