The precision of even the most advanced pipette is only as reliable as the tip you attach to it. Using low-quality or incompatible tips is a primary cause of measurement error and can compromise the airtight seal required for reproducible results. To safeguard your research and ensure a perfect fit, selecting the right tip is essential.

 

Choosing the Right Tip for Your Application

Different laboratory workflows require specific tip characteristics to ensure sample integrity. Below is a guide to selecting the most suitable tip for your needs:

 

Application Recommended Tip Type
PCR / Molecular Biology Filter tips
Contamination-Sensitive Assays Filter tips
Sterile Routine Pipetting Racked tips
High-Volume / Cost-Sensitive Work Economy (Bulk) tips

 

Understanding Tip Characteristics

  • Filter Tips: Feature an aerosol barrier to prevent cross-contamination between the pipette and the sample.
  • Racked Tips: Pre-sterilized and supplied in racks (typically 96 tips) to minimize contamination risk and increase convenience.
  • Economy Tips: Non-sterile polypropylene tips supplied in bulk bags, offering a cost-effective solution for high-throughput labs

 

Infographic guide on how to choose the right pipette tip featuring racked tips for low contamination, filter tips for aerosol protection, and non-sterile bulk tips for cost-effective lab workflows

 

Maximum Accuracy: The Low-Retention Advantage

To achieve true pipetting accuracy, every microliter must be expelled from the tip. LLG Labware low-retention racked tips are engineered specifically for this purpose.

  • Purity: These tips are certified DNase, RNase, and pyrogen-free.
  • Sustainability: Economical refills maximize lab space and reduce environmental impact while protecting your budget.
  • Variety: Available in sterile racked versions or convenient rack refill systems.

 

LLG Labware Universal Compatibility for Major Brands

A common concern is whether the same tip will work across different pipette brands. Our range is designed to deliver a secure, leak-proof seal for all major manufacturers, including Sartorius, BRAND, Thermo Scientific, and Biohit

 

Pipette Brand Popular Models Supported Volume Range Coverage Channel Support
Biohit mLine, Proline 0.1µL to 1000µL 1, 8, 12
Brand Transferpette, Transferpette S 0.1µL to 1000µL  1, 8, 12
Eppendorf Research Plus, Reference 0.1µL to 1000µL  1, 8, 12
Gilson Pipetman Classic, G, L, P10L 0.2µL to 1000µL  1, 8, 12
Nichiryo Nichipet 0.1µL to 1000µL  1, 8, 12
Rainin Pipet-Lite, Classic 0.1µL to 1000µL  1, 8, 12
Thermo/Finn Finnpette 4500 0.2µL to 1000µL  1, 8, 12
Socorex Calibra, Acura 0.1µL to 1000µL  1, 8, 12

 

LLG Labware Specific Compatibility Table

4.694 458 (10x96), 4.694 459 (10x96) and 4.694 460 (8x96) are Sterile, Racked Tips DNase, RNase and pyrogen Free

4.694 454 (10x96), 4.694 455 (10x96) and 4.654 456 (8x96) are Sterile, Rack Refill Tips DNase, RNase and pyrogen Free - Refill Option

 

Brand Model Volume Range Channels

Compatible Part No. 

4.694 458 / 4.694 454*

0.1–10µl

 Compatible Part No. 

4.694 459 / 4.694 455*

200µl

 Compatible Part No. 

4.694 460 / 4.694 456*

1250µl

Biohit mLine 0.1–3µl 1 X    
Biohit mLine 0.5–10µl 1 X    
Biohit mLine 2–20µl 1   X  
Biohit mLine 10–100µl 1   X  
Biohit mLine 20–200µl 1   X  
Biohit mLine 100–1000µl 1     X
Biohit mLine 0.5–10µl 8/12 X    
Biohit mLine 5–100µl 8/12   X  
Biohit mLine 30–300µl 8/12      
Biohit Proline 0.1–2.5µl 1 X    
Biohit Proline 0.5–10µl 1 X    
Biohit Proline 2–20µl 1   X  
Biohit Proline 5–50µl 1   X  
Biohit Proline 10–100µl 1   X  
Biohit Proline 20–200µl 1   X  
Biohit Proline 100–1000µl 1     X
Biohit Proline 0.5–10µl 8/12 X    
Biohit Proline 5–50µl 8/12   X  
Biohit Proline 50–300µl 8/12      
Brand Transferpette 0.1–1µl 1 X    
Brand Transferpette 0.5–10µl 1 X    
Brand Transferpette 2–20µl micro 1 X    
Brand Transferpette 2–20µl 1   X  
Brand Transferpette 5–50µl 1   X  
Brand Transferpette 10–100µl 1   X  
Brand Transferpette 20–200µl 1   X  
Brand Transferpette 100–1000µl 1     X
Brand Transferpette 0.5–10µl 8/12 X    
Brand Transferpette 2–20µl 8/12   X  
Brand Transferpette 2.5–25µl 8/12   X  
Brand Transferpette 5–50µl 8/12   X  
Brand Transferpette 10–100µl 8/12   X  
Brand Transferpette 20–200µl 8/12   X  
Brand Transferpette 30–300µl 8/12      
Brand Transferpette 0.1–1µl 1 X    
Brand Transferpette 0.1–2.5µl 1 X    
Brand Transferpette 0.5–10µl 1 X    
Brand Transferpette 2–20µl 1   X  
Brand Transferpette 10–100µl 1   X  
Brand Transferpette 20–200µl 1   X  
Brand Transferpette 100–1000µl 1     X
Brand Transferpette 0.5–10µl 8/12 X    
Brand Transferpette 5–50µl 8/12   X  
Brand Transferpette 10–100µl 8/12   X  
Brand Transferpette 20–200µl 8/12   X  
Brand Transferpette 30–300µl 8/12      
Eppendorf Research Plus 0.1–2.5µl 1 X    
Eppendorf Research Plus 0.5–10µl 1 X    
Eppendorf Research Plus 2–20µl micro 1 X    
Eppendorf Research Plus 2–20µl 1   X  
Eppendorf Research Plus 10–100µl 1   X  
Eppendorf Research Plus 20–200µl 1   X  
Eppendorf Research Plus 30–300µl 1      
Eppendorf Research Plus 100–1000µl 1     X
Eppendorf Research Plus 0.5–10µl 8/12 X    
Eppendorf Research Plus 10–100µl 8/12   X  
Eppendorf Research Plus 30–300µl 8/12      
Eppendorf Reference 0.1–2.5µl 1 X    
Eppendorf Reference 0.5–10µl 1 X    
Eppendorf Reference 2–20µl micro 1 X    
Eppendorf Reference 2–20µl 1   X  
Eppendorf Reference 10–100µl 1   X  
Eppendorf Reference 50–200µl 1   X  
Eppendorf Reference 100–1000µl 1     X
Gilson Pipetman Classic, G, L: P2 0.2–2µl 1 X    
Gilson Pipetman Classic, G, L: P2 1–10µl 1 X    
Gilson Pipetman Classic, G, L: 2–20µl 1   X  
Gilson Pipetman Classic, G, L: 20–100µl 1   X  
Gilson Pipetman Classic, G, L: 50–200µl 1   X  
Gilson Pipetman Classic, G, L: 200–1000µl 1     X
Gilson Pipetman P10L 0.5–10µl 8/12 X    
Gilson Pipetman P10L 2–20µl 8/12   X  
Gilson Pipetman P10L 20–200µl 8/12   X  
Gilson Pipetman P300L 20–300µl 8/12      
LLG Labware proMLP 0.2–2µl 1 X    
LLG Labware proMLP 0.5–10µl 1 X    
LLG Labware proMLP 2–20µl 1   X  
LLG Labware proMLP 10–100µl 1   X  
LLG Labware proMLP 20–200µl 1   X  
LLG Labware proMLP 100–1000µl 1     X
LLG Labware Microliter pipette, fix 5µl 1   X  
LLG Labware Microliter pipette, fix 10µl 1   X  
LLG Labware Microliter pipette, fix 20µl 1   X  
LLG Labware Microliter pipette, fix 25µl 1   X  
LLG Labware Microliter pipette, fix 50µl 1   X  
LLG Labware Microliter pipette, fix 100µl 1   X  
LLG Labware Microliter pipette, fix 200µl 1   X  
LLG Labware Microliter pipette, fix 250µl 1     X
LLG Labware Microliter pipette, fix 500µl 1     X
LLG Labware Microliter pipette, fix 1000µl 1     X
LLG Labware Microliter pipette, variable 0.1–2.5µl 1 X    
LLG Labware Microliter pipette, variable 0.5–10µl 1 X    
LLG Labware Microliter pipette, variable 2–20µl 1   X  
LLG Labware Microliter pipette, variable 10–100µl 1   X  
LLG Labware Microliter pipette, variable 20–200µl 1   X  
LLG Labware Microliter pipette, variable 100–1000µl 1     X
Nichiryo Nichipet Premium, EX, EX 0.1–2µl 1 X    
Nichiryo Nichipet Premium, EX, EX 2–20µl 1   X  
Nichiryo Nichipet Premium, EX, EX 10–100µl 1   X  
Nichiryo Nichipet Premium, EX, EX 20–200µl 1   X  
Nichiryo Nichipet Premium, EX, EX 100–1000µl 1     X
Nichiryo Nichipet 7000 0.5–10µl 8/12 X    
Nichiryo Nichipet 7000 5–50µl 8/12   X  
Nichiryo Nichipet 7000 40–200µl 8/12   X  
Nichiryo Nichipet 7000 50–300µl 8/12      
Rainin Pipet-Lite SL-2XLS 0.1–2µl 1 X    
Rainin Pipet-Lite SL-2XLS 0.5–10µl 1 X    
Rainin Pipet-Lite SL-20XLS 2–20µl 1   X  
Rainin Pipet-Lite SL-20XLS 10–100µl 1   X  
Rainin Pipet-Lite SL-20XLS 20–200µl 1   X  
Rainin Pipet-Lite 20–300µl 1      
Rainin Pipet-Lite 100–1000µl 1     X
Rainin Classic PR-2 0.1–2µl 1 X    
Rainin Classic PR-2 0.5–10µl 1 X    
Rainin Classic PR-20 2–20µl 1   X  
Rainin Classic PR-20 10–100µl 1   X  
Rainin Classic PR-20 20–200µl 1   X  
Rainin Classic PR-1000 100–1000µl 1     X
Socorex Calibra 822 0.2–2µl 1 X    
Socorex Calibra 822 1–10µl 1 X    
Socorex Calibra 822 2–20µl 1   X  
Socorex Calibra 822 10–100µl 1   X  
Socorex Calibra 822 20–200µl 1   X  
Socorex Calibra 822 100–1000µl 1     X
Socorex Calibra 852 1–10µl 8 X    
Socorex Calibra 852 10–100µl 8/12   X  
Socorex Calibra 852 20–200µl 8/12   X  
Socorex Acura 825 0.1–2µl 1 X    
Socorex Acura 825 0.5–10µl 1 X    
Socorex Acura 825 1–10µl 1 X    
Socorex Acura 825 2–20µl 1   X  
Socorex Acura 825 5–50µl 1   X  
Socorex Acura 825 10–100µl 1   X  
Socorex Acura 825 20–200µl 1   X  
Socorex Acura 825 100–1000µl 1     X
Socorex Acura 825 0.5–10µl 8/12 X    
Socorex Acura 825 5–50µl 8/12   X  
Socorex Acura 825 2–20µl 8/12   X  
Socorex Acura 825 40–350µl 8/12      
Thermo/Finn Finnpette 4500 0.2–2µl 1 X    
Thermo/Finn Finnpette 4500 micro 1 X    
Thermo/Finn Finnpette 4500 0.5–5µl 1 X    
Thermo/Finn Finnpette 4500 2–20µl 1   X  
Thermo/Finn Finnpette 4500 5–50µl 1   X  
Thermo/Finn Finnpette 4500 100–1000µl 1     X
Thermo/Finn Finnpette 4500 0.5–10µl 8/12 X    
Thermo/Finn Finnpette 4500 5–50µl 8/12   X  
Thermo/Finn Finnpette 4500 50–300µl 8/12      

 

* Refill Option

Switching to a refill system is an effective way to enhance laboratory sustainability without compromising on quality or performance. By opting for our pipette tip refill packs instead of standard boxed sets, you significantly reduce plastic waste and environmental impact, as the system allows you to reuse existing racks. Beyond the ecological benefits, these economical refills help you maximize valuable lab storage space and protect your budget, while still maintaining the rigorous DNase, RNase, and pyrogen-free standards required for sensitive research

 

Technical & Compatibility FAQ

 

Which pipette brands are compatible with LLG Labware tips?

LLG Labware low-retention tips are designed for universal fitment with major industry brands. This includes, but is not limited to:

  • Eppendorf: Research Plus and Reference models.

  • Gilson: Pipetman Classic, G, and L series.

  • Brand: Transferpette and Transferpette S.

  • Thermo Scientific: Finnpipette 4500 and various micro models.

  • Sartorius/Biohit: mLine and Proline pipettes.

     

What is the difference between Racked, Filter, and Economy tips?

Choosing the right format depends on your sterility requirements and budget:

  • Filter Tips: Best for molecular biology and PCR to prevent aerosol contamination.

  • Racked Tips: Ideal for sterile routine pipetting and diagnostics, provided in a convenient 96-tip tray.

  • Economy (Bulk) Tips: The most cost-effective solution for high-volume, non-sterile routine liquid handling.

     

     

Are LLG Labware tips certified free of contaminants?

Yes. The LLG Labware low-retention racked tips and rack refill systems are certified DNase, RNase, and pyrogen-free. This ensures they are suitable for sensitive molecular biology assays and contamination-sensitive research.

 

Why is "Low-Retention" important for pipetting accuracy?

For maximum accuracy, every microliter of liquid needs to be expelled from the tip. Low-retention technology reduces the amount of liquid that sticks to the inner walls of the tip, ensuring precise volume delivery and minimizing sample loss.

 

How do I match the correct tip volume to my pipette?

You must match the volume range of your pipette to the corresponding tip size to ensure an airtight seal. For example:

  • 0.1–10µl pipettes typically require tips with reference code 4.694 458 or 4.694 454.

  • 20–200µl pipettes generally utilize tips with reference code 4.694 459 or 4.694 455.

  • 100–1000µl pipettes require the larger 4.694 460 or 4.694 456 variants.

 

Browse our complete range of pipette tips here 

 

Need help deciding what pipette to choose for your application then explore How to Choose the Right Pipette: The Ultimate Guide to Accuracy and Lab Efficiency

Related Stories

The Ultimate Guide to Choosing the Right Laboratory Mixer
The Ultimate Guide to Choosing the Right Laboratory Mixer

Explanation of the different types of mixers used in laboratories

Read full story

7 minutes read

The Scientist’s Guide to Laboratory Glassware: Material, Precision, and Selection
The Scientist’s Guide to Laboratory Glassware: Material, Precision, and Selection

Guide to choosing glassware

Read full story

2 minutes read

Laboratory Centrifuge Maintenance: A Guide to Safety and Longevity
Laboratory Centrifuge Maintenance: A Guide to Safety and Longevity

Centrifuge Maintenance Guide

Read full story

2 minutes read

Why Regenerated Cellulose (RC) Membranes are The Universal Standard for Lab Filtration
Why Regenerated Cellulose (RC) Membranes are The Universal Standard for Lab Filtration

Cellulose as a filtration medium

Read full story

2 minutes read