The Eppendorf Mastercycler X40 sets a new standard in endpoint PCR. It combines a 96-well aluminium thermoblock with a 12-column gradient and excellent temperature homogeneity for highly reproducible results. A large, intuitive touchscreen interface and a SafeLid that adapts to different vessel heights ensure optimal heat transfer and protection against evaporation. Comprehensive user management and GLP- and audit-compliant run documentation make it well suited to regulated environments.
With outstanding temperature uniformity, an intuitive touchscreen and strong compliance features, the Eppendorf Mastercycler X40 is an excellent choice for laboratories seeking fast, reproducible and well-documented PCR.
£7,650.72
Inc. VAT
Manufacturer P/N
6381000042
Part Number
4.701 083
Manufacturer
Eppendorf
Plug type
UK
Manufacturer P/N
6381000018
Part Number
6.325 777
Manufacturer
Eppendorf
Plug type
EU/US/JP/TW
It combines a 96-well aluminium thermoblock with a 12-column gradient and excellent temperature homogeneity for highly reproducible results. A large, intuitive touchscreen interface and a SafeLid that adapts to different vessel heights ensure optimal heat transfer and protection against evaporation. Comprehensive user management and GLP and audit-compliant run documentation make it well suited to regulated environments.
Yes. It is designed for the laboratory application described by the manufacturer, and offers a format of 96-well thermal cycler for endpoint PCR and a power supply of 100-240 V to support this kind of work.
It has a format of 96-well thermal cycler for endpoint PCR and a power supply of 100-240 V.
It offers aluminium block with 12-column gradient, large, intuitive touchscreen, safeLid adapts to different vessel heights and user management with GLP and audit-compliant documentation.

27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure

19 mins read
SPE Consumables Procurement Checklist for UK Analytical Laboratories

24 mins read
Bottle Labelling and Traceability for Lab Managers - Reducing Confusion, Waste and Reorder Errors

21 mins read
How to Standardise Pipette Tip Procurement Across Laboratory Teams

33 mins read
Dissolved Oxygen Calibration and Verification for Laboratory Measurement