DOSTMANN Cryo Data Logger LOG100, -200...450°C, IP65 Watertight
Representative image only

DOSTMANN Cryo Data Logger LOG100, -200...450°C, IP65 Watertight

Sold by: Labfriend UK
Available Soon
Part #: 9.726 429Manufacturer #: 5005-0105
Estimated shipping time:Contact us via live chat or via contact us page

£117.92

Excl. VAT
See the available (1) variant product

Product overview

The DOSTMANN Cryo Data Logger LOG100 is a high-precision instrument engineered for monitoring temperature in extreme environments. With a wide measurement range from -200°C to +450°C, this versatile device ensures reliable performance in both cryogenic and industrial settings. Its IP65-rated waterproof housing makes it ideal for demanding conditions such as laboratories, storage facilities, and manufacturing environments where accuracy and durability are essential.

Key Features:

  • Brand: DOSTMANN
  • Temperature Range: -200°C to +450°C
  • Display: Large screen showing actual values and battery status
  • Memory Capacity: Stores up to 60,000 data sets for long-term monitoring
  • IP Rating: IP65 – waterproof and dustproof for use in harsh environments
  • Software: Easy-to-use software for data management and analysis
  • Applications: Ideal for cryogenics, pharma fridge monitoring, laboratory use, power plants, and production/storage surveillance under HACCP
  • Durability: Robust construction designed for reliability in extreme conditions

Note: Please order software with USB cable separately (9.726 413).

The DOSTMANN Cryo Data Logger LOG100 combines precision, ruggedness, and versatility—making it the ideal choice for accurate temperature monitoring across a wide range of professional and industrial applications.



Frequently Asked Questions

1. What is the DOSTMANN Cryo Data Logger LOG100, -200 to 450°C, IP65 Watertight used for?

It is a high-precision instrument engineered for monitoring temperature in extreme environments. With a wide measurement range from -200°C to +450°C, this versatile device ensures reliable performance in both cryogenic and industrial settings. Its IP65-rated waterproof housing makes it ideal for demanding conditions such as laboratories, storage facilities, and manufacturing environments where accuracy and durability are essential.

2. Is the DOSTMANN Cryo Data Logger LOG100, -200 to 450°C, IP65 Watertight suitable for cryogenics, pharma fridge monitoring, laboratory use, power plants, and production/storage surveillance under HACCP?

Yes. It is designed for cryogenics, pharma fridge monitoring, laboratory use, power plants, and production/storage surveillance under HACCP, and offers -200°C to +450°C and large screen showing actual values and battery status to support this kind of work.

3. What temperature range and display does the DOSTMANN Cryo Data Logger LOG100, -200 to 450°C, IP65 Watertight have?

It has -200°C to +450°C, large screen showing actual values and battery status and stores up to 60,000 data sets for long-term monitoring, and is supplied under manufacturer part number 5005-0105.

4. What IP rating and software does the DOSTMANN Cryo Data Logger LOG100, -200 to 450°C, IP65 Watertight offer?

It offers IP65 – waterproof and dustproof for use in harsh environments, easy-to-use software for data management and analysis, robust construction designed for reliability in extreme conditions and quality surveillance in laboratories, at the production or in the storage.

5. How does the DOSTMANN Cryo Data Logger LOG100, -200 to 450°C, IP65 Watertight compare with the Ebro Pressure And Temperature Data Logger EBI 12-TP231-EX, 2-Channel, External, Luer Lock Pressure Connection from Ebro?

For cryogenics, pharma fridge monitoring, laboratory use, power plants, and production/storage surveillance under HACCP, the Dostmann model is the better choice, offering -200°C to +450°C, large screen showing actual values and battery status and stores up to 60,000 data sets for long-term monitoring. The Ebro model offers 2 channels as an alternative, while the Dostmann model's -200°C to +450°C and large screen showing actual values and battery status help make it a strong fit for cryogenics, pharma fridge monitoring, laboratory use, power plants, and production/storage surveillance under HACCP.

Product Specifications

  • HS Code #90251900
  • Battery/ rechargeable battery1 x CR2032
  • Depth88 mm
  • Designation IECCR2032
  • Dimensions (WxDxH)55 x 88 x 20 mm
  • DisposableNo
  • Height20 mm
  • IP codeIP 65
  • Max. measuring cycle24 h
  • Max. temp. (external)350 °C
  • Max. temperature70 °C
  • Measuring cycle1 sec ... 24 h
  • Min. measuring cycle1 sec
  • Min. temp. (external)-200 °C
  • Min. temperature-10 °C
  • No. of batteries/ rechargeable batteries1
  • Resolution0.1 °C
  • Temperature external-200 ... 350 °C
  • Temperature-10 ... 70 °C
  • TypeLOG100 Cryo
  • Type of auxiliary energyBattery
  • UNSPSC41111979
  • Weight95 g
  • Width55 mm
  • With external sensorNo

Downloads