27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Ø
UNSPSC
Specifications
Compare modelsAlternative in-stock items
£32.96
Inc. VAT
The Cytiva Whatman Grade 934-AH Glass Microfibre Filter is a binder-free glass microfibre filter for suspended solids determination in water pollution monitoring. It offers high retention at high flow rates and is widely used in water pollution monitoring for suspended solids, as specified in US Method 934-AH. This item is supplied as 25 mm circles in a pack of 100, manufacturer part number 1827-025.
Choose the Cytiva Whatman Grade 934-AH in the size and pack quantity that matches your set-up, and check that it fits your filter funnels and holders before ordering.
£32.96
Inc. VAT
Manufacturer P/N
1827-025
Part Number
6.325 342
Manufacturer
Cytiva
Ø
25 mm
Manufacturer P/N
1827-090
Part Number
9.056 732
Manufacturer
Cytiva
Ø
90 mm
Manufacturer P/N
1827-047
Part Number
9.056 727
Manufacturer
Cytiva
Ø
47 mm
Manufacturer P/N
1827-070
Part Number
9.056 731
Manufacturer
Cytiva
Ø
70 mm
£267.17
Inc. VAT
Manufacturer P/N
1827-125
Part Number
9.056 734
Manufacturer
Cytiva
Ø
125 mm
£221.76
Inc. VAT
Manufacturer P/N
1827-110
Part Number
9.056 733
Manufacturer
Cytiva
Ø
110 mm
£97.75
Inc. VAT
Manufacturer P/N
1827-055
Part Number
9.056 730
Manufacturer
Cytiva
Ø
55 mm
£32.96
Inc. VAT
Manufacturer P/N
1827-024
Part Number
9.056 667
Manufacturer
Cytiva
Ø
24 mm
£39.55
Inc. VAT
Manufacturer P/N
1827-032
Part Number
7.658 521
Manufacturer
Cytiva
Ø
32 mm
£29.74
Inc. VAT
Manufacturer P/N
1827-021
Part Number
6.401 540
Manufacturer
Cytiva
Ø
21 mm
£295.68
Inc. VAT
Manufacturer P/N
1827-150
Part Number
6.205 374
Manufacturer
Cytiva
Ø
150 mm
£135.60
Inc. VAT
Manufacturer P/N
1827-082
Part Number
6.322 095
Manufacturer
Cytiva
Ø
82 mm
£354.82
Inc. VAT
Manufacturer P/N
1827-185
Part Number
6.259 503
Manufacturer
Cytiva
Ø
185 mm
£36.15
Inc. VAT
Manufacturer P/N
1827-030
Part Number
7.910 934
Manufacturer
Cytiva
Ø
30 mm
£43.42
Inc. VAT
Manufacturer P/N
1827-037
Part Number
6.326 422
Manufacturer
Cytiva
Ø
37 mm
£174.24
Inc. VAT
Manufacturer P/N
1827-105
Part Number
7.970 150
Manufacturer
Cytiva
Ø
105 mm
£47.42
Inc. VAT
Manufacturer P/N
1827-042
Part Number
9.056 717
Manufacturer
Cytiva
Ø
42.5 mm
It is used for suspended solids determination in water pollution monitoring. It offers high retention at high flow rates and is widely used in water pollution monitoring for suspended solids, as specified in US Method 934-AH.
Yes. Grade 934-AH is widely used in water pollution monitoring for suspended solids and is specified in US Method 934-AH.
This item is 25 mm and is supplied as a pack of 100, manufacturer part number 1827-025.
Select the size that matches your funnel, filter holder or apparatus. If you are replacing an existing filter, compare the grade, size and pack quantity with the item you currently use.
The Macherey-Nagel MN GF-3 Glass Fibre Filter is a binder-free glass fibre filter with 0.6 µm retention capacity that Macherey-Nagel lists for collecting suspended solids in potable water and waste water. By comparison, the Cytiva Whatman Grade 934-AH Glass Microfibre Filter is a binder-free glass microfibre filter for suspended solids determination in water pollution monitoring. Choose the Cytiva Whatman product when your method or existing set-up specifies it; the Macherey-Nagel product may be preferable if you want a filter that Macherey-Nagel lists for suspended solids with 0.6 µm retention. They are alternatives from different brands, so validate the grade against your method before switching.

27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure

19 mins read
SPE Consumables Procurement Checklist for UK Analytical Laboratories

24 mins read
Bottle Labelling and Traceability for Lab Managers - Reducing Confusion, Waste and Reorder Errors

21 mins read
How to Standardise Pipette Tip Procurement Across Laboratory Teams

33 mins read
Dissolved Oxygen Calibration and Verification for Laboratory Measurement