
27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Specifications
£1,423.49
Inc. VAT
The Cytiva Whatman Grade GF/D Glass Microfibre Filter is a binder-free glass microfibre filter for fast filtration of heavily loaded liquids and use as a prefilter ahead of finer filters. This thick filter retains particles of around 3 µm, combining a very high loading capacity with extremely high filtration speed. This item is supplied as 460 x 570 mm sheets in a pack of 25, manufacturer part number 1823-915.
Choose the Cytiva Whatman Grade GF/D in the size and pack quantity that matches your set-up, and check that it fits your filter funnels and holders before ordering.
It is used for fast filtration of heavily loaded liquids and use as a prefilter ahead of finer filters. This thick filter retains particles of around 3 µm, combining a very high loading capacity with extremely high filtration speed.
Grade GF/D is a thick glass microfibre filter that retains particles of around 3 µm with a very high loading capacity and extremely high filtration speed.
This item is 460 x 570 mm and is supplied as a pack of 25, manufacturer part number 1823-915.
Select the size that matches your funnel, filter holder or apparatus. If you are replacing an existing filter, compare the grade, size and pack quantity with the item you currently use.
The Macherey-Nagel MN GF-4 Glass Fibre Filter is a binder-free glass fibre filter that Macherey-Nagel describes as having good loading capacity and high flow rates, with a retention capacity of 1.4 µm. By comparison, the Cytiva Whatman Grade GF/D Glass Microfibre Filter is a binder-free glass microfibre filter for fast filtration of heavily loaded liquids and use as a prefilter ahead of finer filters. Choose the Cytiva Whatman product when your method or existing set-up specifies it; the Macherey-Nagel product may be preferable if you prefer a binder-free filter with the 1.4 µm retention listed for MN GF-4. They are alternatives from different brands, so validate the grade against your method before switching.

27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure

19 mins read
SPE Consumables Procurement Checklist for UK Analytical Laboratories

24 mins read
Bottle Labelling and Traceability for Lab Managers - Reducing Confusion, Waste and Reorder Errors

21 mins read
How to Standardise Pipette Tip Procurement Across Laboratory Teams

33 mins read
Dissolved Oxygen Calibration and Verification for Laboratory Measurement