
27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure
Specifications
£21,827.03
Inc. VAT
Cole-Parmer Real-Time qPCR System Eco 48 is a high-specification yet economically priced real-time thermocycler designed for rapid and accurate PCR analysis. Featuring an exceptional thermal block uniformity of ±0.1°C, the Eco 48 system ensures precise temperature control across all wells, optimizing reaction times and reducing reagent costs. This advanced system supports validated sample volumes as low as 5 µl and can complete 40 PCR cycles in as little as 15 minutes when optimized. The unique heating and cooling mechanism guarantees instant temperature uniformity across the 48-well block, eliminating the need for triplicate runs and delivering reliable results faster.
With its innovative technology and user-friendly software, the Eco 48 system ensures researchers achieve consistent, reproducible results while reducing costs and workflow times, making it an excellent investment for modern laboratories.
Cole-Parmer Real-Time qPCR System Eco 48 is a high-specification yet economically priced real-time thermocycler designed for rapid and accurate PCR analysis. Featuring an exceptional thermal block uniformity of ±0.1°C, the Eco 48 system ensures precise temperature control across all wells, optimizing reaction times and reducing reagent costs. This advanced system supports validated sample volumes as low as 5 µl and can complete 40 PCR cycles in as little as 15 minutes when optimized. The unique heating and cooling mechanism guarantees instant temperature uniformity across the 48-well block, eliminating the need for triplicate runs and delivering reliable results faster.
Yes. It is designed for rapid and accurate PCR analysis, and offers a validated reaction volume of 5 to 20 µl per well and a fast cycling of 40 cycles in 40 minutes (down to 15 minutes optimized) to support this kind of work.
It has a validated reaction volume of 5 to 20 µl per well, a fast cycling of 40 cycles in 40 minutes (down to 15 minutes optimized) and 48-well block with size efficiency, 1/8 size of standard 96-well plates.
It offers high temperature uniformity of ±0.1°C immediately after temperature changes, genotyping in just 4 minutes with over 99% accuracy, patented Adaptive LED Control minimizes optical artifacts and prevents premature detector saturation and dual LED excitation wavelengths (452-486 nm & 542-582 nm).

27 mins read
Troubleshooting pH Measurements: Drift, Slow Response and Calibration Failure

19 mins read
SPE Consumables Procurement Checklist for UK Analytical Laboratories

24 mins read
Bottle Labelling and Traceability for Lab Managers - Reducing Confusion, Waste and Reorder Errors

21 mins read
How to Standardise Pipette Tip Procurement Across Laboratory Teams

33 mins read
Dissolved Oxygen Calibration and Verification for Laboratory Measurement