The Xylem WTW CellOx 325 is a membrane-covered galvanic dissolved oxygen sensor designed for precise measurement in water and aqueous solutions. This low-maintenance sensor requires no polarization time, allowing for immediate use in both laboratory and field applications. It features integrated temperature compensation via an NTC 30 kOhm sensor and membrane leakage monitoring, ensuring accurate and reliable readings.
Ideal for applications such as surface water analysis, wastewater treatment, BOD measurements, and various industrial processes, the CellOx 325 ensures efficient and accurate dissolved oxygen monitoring.
£1,149.98
Inc. VAT
Manufacturer P/N
201533
Part Number
9.822 551
Manufacturer
Xylem WTW
Cable length
1.5 m
£1,353.79
Inc. VAT
Manufacturer P/N
201546
Part Number
7.008 259
Manufacturer
Xylem WTW
Cable length
6 m
£1,194.34
Inc. VAT
Manufacturer P/N
201545
Part Number
7.008 258
Manufacturer
Xylem WTW
Cable length
3 m
It is a membrane-covered galvanic dissolved oxygen sensor designed for precise measurement in water and aqueous solutions. This low-maintenance sensor requires no polarization time, allowing for immediate use in both laboratory and field applications. It features integrated temperature compensation via an NTC 30 kOhm sensor and membrane leakage monitoring, ensuring accurate and reliable readings.
Yes. It is designed for precise measurement in water and aqueous solutions, and offers a measurement range of 0 to 50 mg/L O₂ concentration; 0 to 600% O₂ saturation; 0 to 1250 mbar O₂ partial pressure and a temperature range of 0 to 50°C to support this kind of work.
It has a measurement range of 0 to 50 mg/L O₂ concentration; 0 to 600% O₂ saturation; 0 to 1250 mbar O₂ partial pressure and a temperature range of 0 to 50°C.
It offers t99 < 60 seconds, electrolyte filling lasts up to 6 months and calibration vessel.

20 mins read
Troubleshooting Conductivity Measurements: Unstable, Incorrect and Failed Readings

24 mins read
TLC Consumables and Accessories: Plates, Chambers, Applicators and Detection

23 mins read
How Lab Managers Can Standardise Laboratory Bottle Purchasing

33 mins read
The Complete Guide to Laboratory Gloves for UK Laboratories

21 mins read
Switching Pipette Tip Suppliers Without Disrupting Laboratory Workflows