20 mins read
Troubleshooting Conductivity Measurements: Unstable, Incorrect and Failed Readings
Troubleshooting Conductivity Measurements: Unstable, Incorrect and Failed Readings
For ground joint
Length
Opening for stirrer shaft
Specifications
Compare models£1,507.01
Inc. VAT
The Bohlender G-Magnetic Stirrer Head Complete NS 29/32, 8 mm diameter is an advanced solution for efficient stirring in laboratory applications. Featuring a robust PTFE/PEEK construction, it provides excellent chemical resistance and durability. Capable of handling high speeds of up to 1500 rpm and temperatures of up to +250°C, this stirrer head ensures reliable performance even under challenging conditions. Its compact design allows for optimal space usage while maintaining secure mounting and powerful transmission.
This magnetic stirrer head is perfect for laboratories requiring high performance and long-lasting equipment for mixing and stirring operations.
Manufacturer P/N
C 502-08
Part Number
9.197 201
Manufacturer
Bohlender
For ground joint
NS 29/32
Manufacturer P/N
C 512-08
Part Number
9.197 200
Manufacturer
Bohlender
For ground joint
NS 19/26
Manufacturer P/N
C 502-16
Part Number
6.236 791
Manufacturer
Bohlender
For ground joint
NS 29/32
It is an advanced solution for efficient stirring in laboratory applications. Featuring a robust PTFE/PEEK construction, it provides excellent chemical resistance and durability. Capable of handling high speeds of up to 1500 rpm and temperatures of up to +250°C, this stirrer head ensures reliable performance even under challenging conditions. Its compact design allows for optimal space usage while maintaining secure mounting and powerful transmission.
Yes. It is designed for mixing laboratory liquids and solutions in compatible vessels, and offers a shaft diameter of 8 mm and a max speed of 1500 rpm to support this kind of work.
It has a shaft diameter of 8 mm and a max speed of 1500 rpm.
It is made from PTFE/PEEK for durability and chemical resistance. It also offers +250°C, no grease required and powerful transmission of up to 50 Ncm.

20 mins read
Troubleshooting Conductivity Measurements: Unstable, Incorrect and Failed Readings

24 mins read
TLC Consumables and Accessories: Plates, Chambers, Applicators and Detection

23 mins read
How Lab Managers Can Standardise Laboratory Bottle Purchasing

33 mins read
The Complete Guide to Laboratory Gloves for UK Laboratories

21 mins read
Switching Pipette Tip Suppliers Without Disrupting Laboratory Workflows