Product overview

The Xylem WTW OxiTop-IDS AN6 is a high-performance respirometric measuring system designed for the determination of aerobic respiration. This compact setup supports up to 6 measuring points and includes the IS-6 VAR stirring platform, optimized for sample bottles with a larger diameter. Ideal for environmental and laboratory analysis, the system features integrated sensors and Bluetooth connectivity for wireless data handling.

Key Features:

  • Brand: Xylem WTW
  • Model: OxiTop-IDS AN6
  • Power Supply: 100–240 VAC, 50/60 Hz for global compatibility
  • Measuring Points: 6 fully integrated measuring channels
  • Stirring Platform: IS-6 VAR platform suitable for larger sample bottles
  • Application: Determination of aerobic respiration in environmental and biological samples
  • Note: CO₂ absorber NHP 600 and IDS multi-parameter measuring instruments (Multi 3620 IDS Set WL or Multi 3630 IDS Set WL) are required and must be ordered separately

Scope of Supply:

  • 6 x OxiTop-IDS/B measuring heads
  • 6 x sample bottles MF45/1000 (1000 ml)
  • Nitrification inhibitor
  • 6 x magnetic stirring bars
  • Stirring bar retriever
  • 1 x stirring platform IS-6 VAR

This Xylem WTW OxiTop-IDS AN6 system ensures reliable, real-time data collection and is an excellent solution for labs requiring precision and scalability in respirometric testing.



Frequently Asked Questions

1. What is the Xylem WTW OxiTop-IDS AN6, 100–240 VAC, 50/60 Hz – Respirometric Measuring System, 6 Measuring Points, Including Stirring Platform IS-6 VAR used for?

It is a high-performance respirometric measuring system designed for the determination of aerobic respiration. This compact setup supports up to 6 measuring points and includes the IS-6 VAR stirring platform, optimized for sample bottles with a larger diameter. Ideal for environmental and laboratory analysis, the system features integrated sensors and Bluetooth connectivity for wireless data handling.

2. Is the Xylem WTW OxiTop-IDS AN6, 100–240 VAC, 50/60 Hz – Respirometric Measuring System, 6 Measuring Points, Including Stirring Platform IS-6 VAR suitable for Determination of aerobic respiration in environmental and biological samples?

Yes. It is designed for Determination of aerobic respiration in environmental and biological samples, and offers a power supply of 100–240 VAC, 50/60 Hz for global compatibility and measuring points of 6 fully integrated measuring channels to support this kind of work.

3. What power supply and measuring points does the Xylem WTW OxiTop-IDS AN6, 100–240 VAC, 50/60 Hz – Respirometric Measuring System, 6 Measuring Points, Including Stirring Platform IS-6 VAR have?

It has a power supply of 100–240 VAC, 50/60 Hz for global compatibility, measuring points of 6 fully integrated measuring channels and 6 x OxiTop-IDS/B measuring heads, and is supplied under manufacturer part number 209725.

4. What stirring platform and note does the Xylem WTW OxiTop-IDS AN6, 100–240 VAC, 50/60 Hz – Respirometric Measuring System, 6 Measuring Points, Including Stirring Platform IS-6 VAR offer?

It offers IS-6 VAR platform suitable for larger sample bottles and CO₂ absorber NHP 600 and IDS multi-parameter measuring instruments (Multi 3620 IDS Set WL or Multi 3630 IDS Set WL) are required and must be ordered separately.

5. How does the Xylem WTW OxiTop-IDS AN6, 100–240 VAC, 50/60 Hz – Respirometric Measuring System, 6 Measuring Points, Including Stirring Platform IS-6 VAR compare with the Velp Magnetic Stirrer Multistirrer 15-120/240V, Ø 64 mm, 250 mL Stirring Volume from Velp Scientifica?

The Xylem WTW OxiTop-IDS AN6, 100–240 VAC, 50/60 Hz – Respirometric Measuring System, 6 Measuring Points, Including Stirring Platform IS-6 VAR is a strong choice when power supply of 100–240 VAC, 50/60 Hz for global compatibility matches the workflow. The Velp Magnetic Stirrer Multistirrer 15-120/240V, Ø 64 mm, 250 mL Stirring Volume is an alternative offering stirring volume of Up to 250 mL for versatile laboratory use, so the preferred option depends on the required specification and compatibility.

Product Specifications

  • HS Code #90262020
  • Power supply frequency50/60 Hz
  • Max. measured value4000 mg/l
  • Max. pressure1500 hPa
  • Max. voltage240 V
  • Measured range0 ... 4,000 mg/l
  • Measuring time180 d
  • Min. measured value0 mg/l
  • Min. pressure500 hPa
  • Min. voltage100 V
  • No. of measuring positions6
  • Nominal volume bottle1000 ml
  • Power supply100 ... 240 V, 50/60 Hz
  • Pressure500 ... 1,500 hPa
  • TypeOxiTop®-IDS AN6
  • Type of auxiliary energyBattery/mains connection
  • UNSPSC41104207

Downloads

  • LabFriend 6.314 044 ar_bod_anaerob_lab_01_e.pdfDownload
  • LabFriend 6.314 044 ba77045e06_36x0_Multi_OxiTop_BSB_WTW.pdfDownload
  • LabFriend 6.314 044 WTW_999274US_OxiTop-IDS_English_20210917_low.pdfDownload
Variant products

Products related to this item (1)

Just add items to your shopping cart and select “Instant Quote”

View all Xylem WTW products