SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5
Representative image only

SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5

Sold by: Labfriend UK
Available Soon
Part #: 7.023 179Manufacturer #: 285400197
Estimated shipping time:Contact us via live chat or via contact us page

£451.44

Excl. VAT
See the available (25) variant products

Product overview

The SI Analytics Viscometer Ubbelohde 532-31 is a calibrated viscometer designed for automatic viscosity measurement. Featuring a constant K of 5, it is suitable for measuring fluids with higher viscosity. Compliant with ISO/DIN standards, this model ensures reliable and precise results in laboratory viscosity testing applications.

Key Features:

  • Brand: SI Analytics
  • Model: Ubbelohde 532-31
  • Calibration: Calibrated for automatic measurement
  • Capillary No: IIIA
  • Constant: K 5
  • Application: Ideal for automatic viscosity measurement of high-viscosity fluids

This highly accurate viscometer is essential for laboratories that require automatic viscosity measurements with high precision and reliability for thicker liquids.



Frequently Asked Questions:

What is the SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 used for?
The SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 is a laboratory product used for automatic viscosity measurement of high-viscosity fluids. Its documented configuration includes model: Ubbelohde 532-31, and calibration: Calibrated for automatic measurement. It is identified by manufacturer part number 285400197, LabFriend SKU 7.023 179. It should not be selected for applications outside the manufacturer's stated limits or where an unlisted compatibility is required.

Is the SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 suitable for automatic viscosity measurement of high-viscosity fluids?
Yes. The SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 is suitable for automatic viscosity measurement of high-viscosity fluids. Its suitability is determined by model: Ubbelohde 532-31, calibration: Calibrated for automatic measurement, and capillary no: IIIA. It should not be selected for applications outside the manufacturer's stated limits or where an unlisted compatibility is required. Before selection, confirm that the sample, process, vessel or instrument conditions match the published SI Analytics specification.

What are the most important specifications of the SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5?
The most important specifications of the SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 include model: Ubbelohde 532-31, calibration: Calibrated for automatic measurement, capillary no: IIIA, and constant: K 5. The listed item is manufacturer part number 285400197, LabFriend SKU 7.023 179. It should not be selected for applications outside the manufacturer's stated limits or where an unlisted compatibility is required. Specifications not stated in the product description should be confirmed before purchase rather than assumed from a related model.

What is the SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 compatible with, and what is required for use?
The supplied description for the SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 does not confirm a complete compatibility or accessory list. Confirm the stated dimensions, material, operating range, interface and any accessories or consumables not explicitly included. Do not assume compatibility with another model solely because the products appear similar; verify the exact SI Analytics model and manufacturer part number 285400197, LabFriend SKU 7.023 179 before purchase.

What is the difference between the SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 and the SI Analytics Viscometer, Ubbelohde 532-21, Calibrated for Automatic Measurement, Capillary No. IIA, Constant K = 0.5?
The SI Analytics Viscometer, Ubbelohde 532-31, Calibrated for Automatic Measurement, Capillary No. IIIA, Constant K = 5 differs from the SI Analytics Viscometer, Ubbelohde 532-21, Calibrated for Automatic Measurement, Capillary No. IIA, Constant K = 0.5 in the documented model (Ubbelohde 532-31 versus Ubbelohde 532-21), capillary no (IIIA versus IIA). Both are SI Analytics products in the same general product family, but their capacities, ranges or configurations should not be treated as interchangeable. Select the model whose published limits match the application and confirm accessory or connection differences before ordering.

Product Specifications

  • HS Code #90279000
  • CalibrationYes
  • Capacity15 ... 20 ml
  • Constant5
  • Int. Ø3.00 mm
  • Length290 mm
  • Max. measured value5000 mm²/s
  • Measured range500 ... 5,000 mm²/s
  • MeasurementAutomatical
  • Min. measured value500 mm²/s
  • No. of capillaryIIIa
  • StandardISO 3105, DIN 51562
  • Type532 31
  • Type of capillary viscometerUbbelohde
  • UNSPSC41103312
Variant products

Products related to this item (25)

Just add items to your shopping cart and select “Instant Quote”

View all SI Analytics products