SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V
Representative image only

SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V

Sold by: Labfriend UK
Available Soon
Part #: 9.863 178Manufacturer #: 285220930
Estimated shipping time:Contact us via live chat or via contact us page

£8,975.12

Excl. VAT

Product overview

The SI Analytics Titrator Module TL 7750 KF 05 is an advanced titration module designed for Karl Fischer water content analysis. It operates with a main supply range of 100-240 V, providing flexibility for various laboratory settings. The TL 7750 KF 05 ensures high accuracy in water determination, making it an ideal choice for industries such as pharmaceuticals, food, and environmental testing.

Key Features:

  • Brand: SI Analytics
  • Model: Titrator Module TL 7750 KF 05
  • Voltage: Main Supply 100-240 V
  • Application: Used for precise water content analysis through Karl Fischer titration
  • Performance: High-precision titration for reliable results in various industries

Enhance your water content analysis capabilities with the SI Analytics Titrator Module TL 7750 KF 05, ensuring accurate and consistent results for your laboratory's needs.



Frequently Asked Questions:

What is the SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V used for?
The SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V is a laboratory product used for Used for precise water content analysis through Karl Fischer titration. Its documented configuration includes voltage: Main Supply 100-240 V, and model: Titrator Module TL 7750 KF 05. It is identified by manufacturer part number 285220930, LabFriend SKU 9.863 178. It should not be selected for applications outside the manufacturer's stated limits or where an unlisted compatibility is required.

Is the SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V suitable for Used for precise water content analysis through Karl Fischer titration?
Yes. The SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V is suitable for Used for precise water content analysis through Karl Fischer titration. Its suitability is determined by voltage: Main Supply 100-240 V, model: Titrator Module TL 7750 KF 05, and performance: High-precision titration for reliable results in various industries. It should not be selected for applications outside the manufacturer's stated limits or where an unlisted compatibility is required. Before selection, confirm that the sample, process, vessel or instrument conditions match the published SI Analytics specification.

What are the most important specifications of the SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V?
The most important specifications of the SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V include voltage: Main Supply 100-240 V, model: Titrator Module TL 7750 KF 05, and performance: High-precision titration for reliable results in various industries. The listed item is manufacturer part number 285220930, LabFriend SKU 9.863 178. It should not be selected for applications outside the manufacturer's stated limits or where an unlisted compatibility is required. Specifications not stated in the product description should be confirmed before purchase rather than assumed from a related model.

What is the SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V compatible with, and what is required for use?
The SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V has documented compatibility or supply details including voltage: Main Supply 100-240 V. Confirm the stated dimensions, material, operating range, interface and any accessories or consumables not explicitly included. Do not assume that an accessory, fitting, consumable or instrument is compatible unless its dimensions, interface and material requirements match the SI Analytics specification.

What is the difference between the SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V and the SI Analytics Titrator Module TL 7750 KF 10, Main Supply 100-240 V?
The SI Analytics Titrator Module TL 7750 KF 05, Main Supply 100-240 V differs from the SI Analytics Titrator Module TL 7750 KF 10, Main Supply 100-240 V in the documented model (Titrator Module TL 7750 KF 05 versus TL 7750 KF 10 Titrator Module), voltage (Main Supply 100-240 V versus Main supply 100-240 V for versatile use in different laboratory). Both are SI Analytics products in the same general product family, but their capacities, ranges or configurations should not be treated as interchangeable. Select the model whose published limits match the application and confirm accessory or connection differences before ordering.

Product Specifications

  • HS Code #90279000
  • Accuracy pH0.002
  • Accuracy pH±0.002
  • Depth296 mm
  • Dimensions (WxDxH)153 x 296 x 450 mm
  • Dosing accuracy0.15 R%
  • Dosing volume5 ml
  • Power supply frequency50/60 Hz
  • Height450 mm
  • Max. voltage240 V
  • Min. voltage100 V
  • mV range-2000 ... 2000
  • mV range accuracy±0.1 ±1 Digit
  • pH range-3.0 ... 18.00
  • Power supply100 ... 240 V, 50/60 Hz
  • TypeTL7750 KF 05
  • UNSPSC41115602
  • Width153 mm

Just add items to your shopping cart and select “Instant Quote”

View all SI Analytics products